  1. Pure sine wave output
  2. DSP digital contro
  3. Boost and buck AVR for voltage stabilization
  4. Cold start function
  5. Intelligent battery management
  6. Short circuit and overload protection
  7. Off-mode charging
  8. Offering LED and LCD panels for selection
  9. Optional USB, RS232/RJ45/SNMP communication port

TECHNICAL SPECIFICATION:

MODEL UC1K(S)
Capacity 1000VA/800W
INPUT
Voltage range 145~275VAC±5V
Frequency range 50HZ-60HZ
OUTPUT
Output voltage 220VAC
AC voltage range ±10%
Frequency range(Batt.Mode) 50Hz±0.25Hz or 60Hz±0.3Hz
Overload 105%-110%:UPS beep alamm, do not shut down
110%-130%:auto shut down after 30 seconds
>130%:auto shut down immediately
Transfer time 0ms
Wave form(batt.mode) Pure sine wave
BATTERY
Standard model Battery type 12V7Ah
Numbers 2
Charging current(Max.) Assume:1A±10% Max: 1A or 2A for option
Charging voltage 27.3VDC±1%
Long-run model Battery type 12V,AH depending on applicant
Numbers 3
Charging current(Max.) > 5A
Charging voltage 27.4VDC±1%
PHYSICAL
Standard model Dimension LxWxH(mm) 360x147x220
Net weight(kgs) 11.9
Long-run model Dimension LxWxH(mm) 360x147x220
Net weight(kgs) 8.5
ENVIRONMENT
Humidity 20-90%RH@0-40℃(non-condensing)
Noise level Less than 55dBA@1 Meter
MANAGEMENT
Smart RS-232 Support windows 2000/2003/XP/Vista/2008, Windows7/8, Linux, Unix, and MAC
Optional SNMP Power management from SNMP management and web browser

TECHNICAL SPECIFICATION:

MODEL UC2K(S)
Capacity 2000VA/1600W
INPUT
Voltage range 145~275VAC±5V
Frequency range 50HZ-60HZ
OUTPUT
Output voltage 220VAC
AC voltage range ±10%
Frequency range(Batt.Mode) 50Hz±0.25Hz or 60Hz±0.3Hz
Overload 105%-110%:UPS beep alamm, do not shut down
110%-130%:auto shut down after 30 seconds
>130%:auto shut down immediately
Transfer time 0ms
Wave form(batt.mode) Pure sine wave
BATTERY
Standard model Battery type 12V7Ah
Numbers 4
Charging current(Max.) Assume:1A±10% Max: 1A or 2A for option
Charging voltage 54.7VDC±1%
Long-run model Battery type 12V,AH depending on applicant
Numbers 6
Charging current(Max.) > 5A
Charging voltage 82.1VDC±1%
PHYSICAL
Standard model Dimension LxWxH(mm) 440x192x340
Net weight(kgs) 22
Long-run model Dimension LxWxH(mm) 440x192x340
Net weight(kgs) 16
ENVIRONMENT
Humidity 20-90%RH@0-40℃(non-condensing)
Noise level Less than 55dBA@1 Meter
MANAGEMENT
Smart RS-232 Support windows 2000/2003/XP/Vista/2008, Windows7/8, Linux, Unix, and MAC
Optional SNMP Power management from SNMP management and web browser

TECHNICAL SPECIFICATION:

MODEL UC3K(S)
Capacity 3000VAV2400W
INPUT
Voltage range 145~275VAC±5V
Frequency range 50HZ-60HZ
OUTPUT
Output voltage 220VAC
AC voltage range ±10%
Frequency range(Batt.Mode) 50Hz±0.25Hz or 60Hz±0.3Hz
Overload 105%-110%:UPS beep alamm, do not shut down
110%-130%:auto shut down after 30 seconds
>130%:auto shut down immediately
Transfer time 0ms
Wave form(batt.mode) Pure sine wave
BATTERY
Standard model Battery type 12V7Ah
Numbers 6
Charging current(Max.) Assume:1A±10% Max: 1A or 2A for option
Charging voltage 82.0VDC±1%
Long-run model Battery type 12V,AH depending on applicant
Numbers 8
Charging current(Max.) > 5A
Charging voltage 109.4VDC±1%
PHYSICAL
Standard model Dimension LxWxH(mm) 440x192x340
Net weight(kgs) 27.9
Long-run model Dimension LxWxH(mm) 440x192x340
Net weight(kgs) 18.2
ENVIRONMENT
Humidity 20-90%RH@0-40℃(non-condensing)
Noise level Less than 55dBA@1 Meter
MANAGEMENT
Smart RS-232 Support windows 2000/2003/XP/Vista/2008, Windows7/8, Linux, Unix, and MAC
Optional SNMP Power management from SNMP management and web browser

TECHNICAL SPECIFICATION:

MODEL UC6K(S)
Capacity 6000VA/4.8KW
INPUT
Voltage range 165-275VAC±5V
Frequency range 50HZ-60HZ
OUTPUT
Output voltage 220VAC
AC voltage range ±10%
Frequency range(Batt.Mode) 50Hz±0.25Hz or 60Hz±0.3Hz
Overload 105%-110%:UPS beep alamm, do not shut down
110%-130%:auto shut down after 30 seconds
>130%:auto shut down immediately
Transfer time 0ms
Wave form(batt.mode) Pure sine wave
BATTERY
Standard model Battery type 12V7Ah
Numbers /
Charging current(Max.) Assume:1A±10% Max: 1A or 2A for option
Charging voltage 218.4V±1%
Long-run model Battery type 12V,AH depending on applicant
Numbers 16
Charging current(Max.) > 5A
Charging voltage 218.4V±1%
PHYSICAL
Standard model Dimension LxWxH(mm) /
Net weight(kgs) /
Long-run model Dimension LxWxH(mm) 520x240x460
Net weight(kgs) 30.5
ENVIRONMENT
Humidity 20-90%RH@0-40℃(non-condensing)
Noise level Less than 55dBA@1 Meter
MANAGEMENT
Smart RS-232 Support windows 2000/2003/XP/Vista/2008, Windows7/8, Linux, Unix, and MAC
Optional SNMP Power management from SNMP management and web browser

TECHNICAL SPECIFICATION:

MODEL UC10K(S)
Capacity 10KVA/8KW
INPUT
Voltage range 165-275VAC±5V
Frequency range 50HZ-60HZ
OUTPUT
Output voltage 220VAC
AC voltage range ±10%
Frequency range(Batt.Mode) 50Hz±0.25Hz or 60Hz±0.3Hz
Overload 105%-110%:UPS beep alamm, do not shut down
110%-130%:auto shut down after 30 seconds
>130%:auto shut down immediately
Transfer time 0ms
Wave form(batt.mode) Pure sine wave
BATTERY
Standard model Battery type 12V7Ah
Numbers /
Charging current(Max.) Assume:1A±10% Max: 1A or 2A for option
Charging voltage 218.4V±1%
Long-run model Battery type 12V,AH depending on applicant
Numbers 16
Charging current(Max.) > 5A
Charging voltage 218.4V±1%
PHYSICAL
Standard model Dimension LxWxH(mm) /
Net weight(kgs) /
Long-run model Dimension LxWxH(mm) 520x240x460
Net weight(kgs) 35
ENVIRONMENT
Humidity 20-90%RH@0-40℃(non-condensing)
Noise level Less than 55dBA@1 Meter
MANAGEMENT
Smart RS-232 Support windows 2000/2003/XP/Vista/2008, Windows7/8, Linux, Unix, and MAC