All Categories
Rack mounted UPS

Home /  Products /  UPS /  Rack mounted UPS

Lead-acid battery Rack mounted UPS

  • Overview
  • Recommended Products

Product Features:

  • Trulyachieve online double conversion
  • Microprocessorcontrolensures high reliability
  • Inputpowerfactor correction
  • Output power factor up to 0.9
  • Wide utilityinputrange(110V-300V)
  • Efficientfrequency conversion mode
  • Compatible with generators
  • External battery ups charging current up to 6A

Products specifications:

Model C1KR(S)
Phase Single-phase
Capacity 1KVA/900W
Input
Input voltage 100/110/115/120/127VAC or 200/208/220/230/240VCA
Voltage range

55-145VAC/110-300VAC@50% load

85-140VAC/160-280VAC@100%load

Input frequency 46-54Hz or 56-64Hz
Factor ≥0.99@100% load
Output
Output voltage 100/110/115/120/127VAC or 200/208/220/230/240VCA
Voltage range (battery mode) ±1%
Frequency (synchronous range) 46-54Hz/56-64Hz
Frequency range (Battery Mode) 50Hz±0.25Hz/60Hz±0.3Hz
Peak factor 3:1
Waveform balance

≤3%THD Linear Load

≤6%THD Non-linear Load

Transfer time 0ms
Output waveform Pure Sine Wave

Efficiency

Mains power mode 92%
Battery mode 90%
Stardard UPS
Stardard UPS
Battery model 12V/7AH
battery amount 2
Charging time 4 hours to be 90% full capacity
Max charging current 1A
Charging voltage 27.4VDC

Machine data

Size(MM) 400*438*88
Weight(KG) 11.2
External battery UPS

External battery UPS

Battery model Depends on the applicant
Batteries quantity 2/3
Max charging current 1A/2A/4A/6A adjustable
Charging voltage 27.4VDC±1%/41VDC±1%

Machine data

Size(MM) 400*438*88
Weight(KG) 5.6
Display instructions
LCD
Load size,battery capacity,mains mode,battery mode,bypass mode,fault indication
Working environment
Humidity
20-90%RH@0-40 No condensation
Noise
<50dBA@1M
Control management
SmartRS-232/USB
Be in favor of Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, MAC

Optional SNMP

Power management supports SNMP management and network management

Products specifications:

Model C2KR(S)
Phase Single-phase
Capacity 2KVA/1800W
Input
Input voltage 100/110/115/120/127VAC or 200/208/220/230/240VCA
Voltage range

55-145VAC/110-300VAC@50% load

85-140VAC/160-280VAC@100%load

Input frequency 46-54Hz or 56-64Hz
Factor ≥0.99@100% load
Output
Output voltage 100/110/115/120/127VAC or 200/208/220/230/240VCA
Voltage range (battery mode) ±1%
Frequency (synchronous range) 46-54Hz/56-64Hz
Frequency range (Battery Mode) 50Hz±0.25Hz/60Hz±0.3Hz
Peak factor 3:1
Waveform balance

≤3%THD Linear Load

≤6%THD Non-linear Load

Transfer time 0ms
Output waveform Pure Sine Wave

Efficiency

Mains power mode 92%
Battery mode 90%
Stardard UPS
Stardard UPS
Battery model 12V/7AH
battery amount 4
Charging time 4 hours to be 90% full capacity
Max charging current 1A
Charging voltage 54.7VDC

Machine data

Size(MM) 400*438*88
Weight(KG) 16.3
External battery UPS

External battery UPS

Battery model Depends on the applicant
Batteries quantity 4
Max charging current 1A/2A/4A/6A adjustable
Charging voltage 54.7VDC±1%

Machine data

Size(MM) 400*438*88
Weight(KG) 8.6
Display instructions
LCD
Load size,battery capacity,mains mode,battery mode,bypass mode,fault indication
Working environment
Humidity
20-90%RH@0-40 No condensation
Noise
<50dBA@1M
Control management
SmartRS-232/USB
Be in favor of Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, MAC

Optional SNMP

Power management supports SNMP management and network management

Products specifications:

Model C3KR(S)
Phase Single-phase
Capacity 3KVA/2700W
Input
Input voltage 100/110/115/120/127VAC or 200/208/220/230/240VCA
Voltage range

55-145VAC/110-300VAC@50% load

85-140VAC/160-280VAC@100%load

Input frequency 46-54Hz or 56-64Hz
Factor ≥0.99@100% load
Output
Output voltage 100/110/115/120/127VAC or 200/208/220/230/240VCA
Voltage range (battery mode) ±1%
Frequency (synchronous range) 46-54Hz/56-64Hz
Frequency range (Battery Mode) 50Hz±0.25Hz/60Hz±0.3Hz
Peak factor 3:1
Waveform balance

≤3%THD Linear Load

≤6%THD Non-linear Load

Transfer time 0ms
Output waveform Pure Sine Wave

Efficiency

Mains power mode 92%
Battery mode 90%
Stardard UPS
Stardard UPS
Battery model 12V/7AH
battery amount 4
Charging time 4 hours to be 90% full capacity
Max charging current 1A
Charging voltage 54.7VDC

Machine data

Size(MM) 400*438*88
Weight(KG) 17.2
External battery UPS

External battery UPS

Battery model Depends on the applicant
Batteries quantity 4/6
Max charging current 1A/2A/4A/6A adjustable
Charging voltage 54.7VDC±1%/82.1VDC±1%

Machine data

Size(MM) 400*438*88
Weight(KG) 8.6
Display instructions
LCD
Load size,battery capacity,mains mode,battery mode,bypass mode,fault indication
Working environment
Humidity
20-90%RH@0-40 No condensation
Noise
<50dBA@1M
Control management
SmartRS-232/USB
Be in favor of Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, MAC

Optional SNMP

Power management supports SNMP management and network management

Products specifications:

Model C6KR(S)
Phase Single-phase
Capacity 6KVA/4800W
Input
Input voltage 100/110/115/120/127VAC or 200/208/220/230/240VCA
Voltage range

110-300VAC±3%@50% load

176-300VAC±3%@100% load

Input frequency 46-54Hz or 56-64Hz
Factor ≥0.99@100% load
Output
Output voltage 100/110/115/120/127VAC or 200/208/220/230/240VCA
Voltage range (battery mode) ±1%
Frequency (synchronous range) 46-54Hz/56-64Hz
Frequency range (Battery Mode) 50Hz/60HZ±0.1HZ
Peak factor 3:1
Waveform balance

≤3%THD Linear Load

≤6%THD Non-linear Load

Transfer time 0ms
Output waveform Pure Sine Wave

Efficiency

Mains power mode 92%
Battery mode 90%
Stardard UPS
Stardard UPS
Battery model -
battery amount -
Charging time -
Max charging current -
Charging voltage -

Machine data

Size(MM) 400*438*88
Weight(KG) -
External battery UPS

External battery UPS

Battery model Depends on the applicant
Batteries quantity 16-20(adjustable)
Max charging current 1A/2A/4A/6A adjustable
Charging voltage 218.4VDC±1%(Based on 16pcs batteries)

Machine data

Size(MM) 400*438*88
Weight(KG) 13
Display instructions
LCD
Load size,battery capacity,mains mode,battery mode,bypass mode,fault indication
Working environment
Humidity
20-90%RH@0-40 No condensation
Noise
<50dBA@1M
Control management
SmartRS-232/USB
Be in favor of Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, MAC

Optional SNMP

Power management supports SNMP management and network management

Products specifications:

Model C10KR(S)
Phase Single-phase
Capacity 10KVA/8000W
Input
Input voltage 100/110/115/120/127VAC or 200/208/220/230/240VCA
Voltage range

110-300VAC±3%@50% load

176-300VAC±3%@100% load

Input frequency 46-54Hz or 56-64Hz
Factor ≥0.99@100% load
Output
Output voltage 100/110/115/120/127VAC or 200/208/220/230/240VCA
Voltage range (battery mode) ±1%
Frequency (synchronous range) 46-54Hz/56-64Hz
Frequency range (Battery Mode) 50Hz/60HZ±0.1HZ
Peak factor 3:1
Waveform balance

≤3%THD Linear Load

≤6%THD Non-linear Load

Transfer time 0ms
Output waveform Pure Sine Wave

Efficiency

Mains power mode 93%
Battery mode 91%
Stardard UPS
Stardard UPS
Battery model -
battery amount -
Charging time -
Max charging current -
Charging voltage -

Machine data

Size(MM) 400*438*88
Weight(KG) -
External battery UPS

External battery UPS

Battery model Depends on the applicant
Batteries quantity 16-20(adjustable)
Max charging current 1A/2A/4A/6A adjustable
Charging voltage 218.4VDC±1%(Based on 16pcs batteries)

Machine data

Size(MM) 400*438*88
Weight(KG) 17
Display instructions
LCD
Load size,battery capacity,mains mode,battery mode,bypass mode,fault indication
Working environment
Humidity
20-90%RH@0-40 No condensation
Noise
<50dBA@1M
Control management
SmartRS-232/USB
Be in favor of Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, MAC

Optional SNMP

Power management supports SNMP management and network management

Get a Free Quote

Our representative will contact you soon.
Email
Whatsapp
Name
Company Name
Message
0/1000

Get a Quote

Demand type
Name
Country
Company Name
Mobile
Email
Message
0/1000