Multi socket backup ups
Features:
- Intelligent CPU control
- Auto restart while AC is recovering
- Boost and buck AVR for voltage stabilization
- Cold start function
- Off-mode charging
- Optional USB or RJ45 port.
- Offering LCD panel for selection, multi-color panel.
- The UPS has mute function when the UPS in Battery mode.
- The LCD display can be off when the UPS in AC/ Battery mode.
- Overview
- Recommended Products
Main technical parameters:
| MODEL | AR650 |
| Capacity | 650VA/360W |
| INPUT | |
| Voltage | 110V/120 VAC or 220/230/240 VAC |
| Voltage range | 81-145VAC or 145-275VAC |
| Frequency | 60/50 Hz(Auto sensing) |
| OUTPUT | |
| Voltage | 110/120 VAC or 220/230/240 VAC |
| Voltage range | ±10% |
| Frequency range(battery mode) | 60/50±1Hz |
| Transfer time | 4-6ms |
| Wave form(battery mode) | Simulated sine wave |
| BATTERY | |
| Battery model & Quantity | 12V/7AHx1 |
| Charge time | 8 hours recover to 90% capacity |
| PROTECTION | |
| Full protection | Discharge, Short circuit and overload protection |
| INDICATORS | |
| LCD display | AC mode, Battery mode, Load level, Battery level, Input voltage, Output voltage, Overload and low battery |
| ALARM | |
| Battery mode | Sounding every 4 seconds |
| Low battery | Sounding every second |
| Overload | Sounding every second |
| Fault | Continuously sounding |
| INTERFACE | |
| RJ45/ USB 5V(2A) | Support windows XP/Vista, Windows 7/8, Linux, Unix, and MAC |
| ENVIRONMENT | |
| Humidity | 0-90% RH @ 0-40C (Non-condensing) |
| Noise Level | Less than 40dB |
| Dimension(mm) | 115*115*40 |
| N.W.(kg) | 5.8 |
Main technical parameters:
| MODEL | AR850 |
| Capacity | 850VA/480W |
| INPUT | |
| Voltage | 110V/120 VAC or 220/230/240 VAC |
| Voltage range | 81-145VAC or 145-275VAC |
| Frequency | 60/50 Hz(Auto sensing) |
| OUTPUT | |
| Voltage | 110/120 VAC or 220/230/240 VAC |
| Voltage range | ±10% |
| Frequency range(battery mode) | 60/50±1Hz |
| Transfer time | 4-6ms |
| Wave form(battery mode) | Simulated sine wave |
| BATTERY | |
| Battery model & Quantity | 12V/9AHx1 |
| Charge time | 8 hours recover to 90% capacity |
| PROTECTION | |
| Full protection | Discharge, Short circuit and overload protection |
| INDICATORS | |
| LCD display | AC mode, Battery mode, Load level, Battery level, Input voltage, Output voltage, Overload and low battery |
| ALARM | |
| Battery mode | Sounding every 4 seconds |
| Low battery | Sounding every second |
| Overload | Sounding every second |
| Fault | Continuously sounding |
| INTERFACE | |
| RJ45/ USB 5V(2A) | Support windows XP/Vista, Windows 7/8, Linux, Unix, and MAC |
| ENVIRONMENT | |
| Humidity | 0-90% RH @ 0-40C (Non-condensing) |
| Noise Level | Less than 40dB |
| Dimension(mm) | |
| N.W.(kg) | 6 |
Main technical parameters:
| MODEL | AR1000 |
| Capacity | 1000VA/600W |
| INPUT | |
| Voltage | 110V/120 VAC or 220/230/240 VAC |
| Voltage range | 81-145VAC or 145-275VAC |
| Frequency | 60/50 Hz(Auto sensing) |
| OUTPUT | |
| Voltage | 110/120 VAC or 220/230/240 VAC |
| Voltage range | ±10% |
| Frequency range(battery mode) | 60/50±1Hz |
| Transfer time | 4-6ms |
| Wave form(battery mode) | Simulated sine wave |
| BATTERY | |
| Battery model & Quantity | 12V/9AHx1 |
| Charge time | 8 hours recover to 90% capacity |
| PROTECTION | |
| Full protection | Discharge, Short circuit and overload protection |
| INDICATORS | |
| LCD display | AC mode, Battery mode, Load level, Battery level, Input voltage, Output voltage, Overload and low battery |
| ALARM | |
| Battery mode | Sounding every 4 seconds |
| Low battery | Sounding every second |
| Overload | Sounding every second |
| Fault | Continuously sounding |
| INTERFACE | |
| RJ45/ USB 5V(2A) | Support windows XP/Vista, Windows 7/8, Linux, Unix, and MAC |
| ENVIRONMENT | |
| Humidity | 0-90% RH @ 0-40C (Non-condensing) |
| Noise Level | Less than 40dB |
| Dimension(mm) | |
| N.W.(kg) | 6 |