Rack Mount Online UPS 1kVA-10kVA with Lead Acid Battery
High Efficiency Rackmount UPS with Stable Pure Sine Wave Output & AVR for IT Room, Server & Network Devices
ShanPu C series (Winner Pro) is a rack mount online UPS from 1kVA to 10kVA - C1KR(S), C2KR(S), C3KR(S), C6KR(S) and C10KR(S) - combining true online double-conversion, pure sine wave output and 0ms transfer time for servers, network rooms and data center equipment. Standard 19-inch 2U models (400×438×88mm) accept 100-127VAC or 200-240VAC systems with a wide input window up to 110-300VAC. Built-in maintenance-free 12V/7Ah lead-acid batteries cover standard models, while external-battery (S) versions extend runtime with up to 6A charging. Efficiency reaches 92% in mains mode and 90% in battery mode, with THD below 3% on linear loads.
Key Features of ShanPu Rack Mount UPS
- True Online Double Conversion: Pure sine wave output with 0ms transfer between mains and battery for sensitive loads.
- Wide-Input Flexibility: 100-127VAC or 200-240VAC selectable systems; input range up to 110-300VAC with input PFC above 1.0.
- High Output Performance: Output power factor up to 1.0, THD below 3% (linear) and peak factor 3:1 for server-grade loads.
- Built-in or External Batteries: Maintenance-free 12V/7Ah lead-acid inside standard models; external battery (S) versions and up to 6A charging extend runtime.
- AVR and Frequency Conversion: Automatic voltage regulation plus efficient frequency conversion mode for unstable grids.
- 2U Rack Form with Full Management: 19-inch 2U cabinet, LCD status display, RS-232/USB and optional SNMP for remote monitoring.
Applications
- Enterprise Server Rooms: Protects servers, storage and network switches against outages and voltage sags.
- Data Centers and Edge Sites: Double conversion and 0ms transfer support racks in small data centers and edge rooms.
- Network Management Centers: Keeps routing, switching and monitoring infrastructure online.
- Industrial and Medical Equipment: Pure sine wave output protects industrial PCs, control, medical and measurement devices.
- Banking, Communication and B2B Projects: Builds reliable power into financial, telecom and channel-integrated projects.
Typical Configurations
- Step 1 - Size the UPS. Add server and network load wattage and select C1KR(S), C2KR(S), C3KR(S), C6KR(S) or C10KR(S) with headroom.
- Step 2 - Choose the voltage system. Select the 100-127VAC or 200-240VAC configuration that matches your site power.
- Step 3 - Decide standard vs external battery. Standard models include 12V/7Ah cells (90% charge in 4 hours); external-battery (S) versions extend runtime for long outages.
- Step 4 - Plan installation. Mount in a standard 19-inch rack (2U), connect RS-232/USB or optional SNMP, and keep the unit within 0-40°C.
Custom/OEM Solutions
Customization covers capacity, input/output voltage configuration, socket panel type, SNMP and communication settings, battery capacity and labeling. For [OEM and ODM power projects], send load list and wattage, voltage system, required backup time, standard or external battery, quantity and destination for a proposal and quotation.
Products specifications:
| Model | C1KR(S) | C2KR(S) | C3KR(S) | C6KR(S) | C10KR(S) | |
| Phase | Single-phase | |||||
| Capacity | 1KVA/1KW | 2KVA/2KW | 3KVA/3KW | 6KVA/6000W | 10KVA/10000W | |
| Input | ||||||
| Input voltage | 100/110/115/120/127VAC or 200/208/220/230/240VAC | |||||
| Voltage range |
55-145VAC/110-300VAC@50% load 85-140VAC/160-280VAC@100%load |
110-300VAC±3%@50% load 176-300VAC±3%@100% load |
||||
| Input frequency | 46-54Hz or 56-64Hz | |||||
| Factor | ≥0.99@100% load | |||||
| Output | ||||||
| Output voltage | 100/110/115/120/127VAC or 200/208/220/230/240VCA | |||||
| Voltage range (battery mode) | ±1% | |||||
| Frequency (synchronous range) | 46-54Hz/56-64Hz | |||||
| Frequency range (Battery Mode) | 50Hz ± 0.25Hz / 60Hz ± 0.3Hz | 50Hz / 60Hz ± 0.1Hz | ||||
| Peak factor | 3:1 | |||||
| Waveform balance |
≤3%THD Linear Load ≤6%THD Non-linear Load |
|||||
| Transfer time | 0ms | |||||
| Output waveform | Pure Sine Wave | |||||
|
Efficiency |
||||||
| Mains power mode | 92% | 92% | 92% | 92% | 93% | |
| Battery mode | 90% | 90% | 90% | 90% | 91% | |
| Stardard UPS |
Battery model | 12V/7AH |
- | |||
| Battery amount | 2 | 4 | 4 | - | - | |
| Charging time | 4 hours to be 90% full capacity | - | - | |||
| Max charging current | 1A | - | - | |||
| Charging voltage | 27.4VDC | 54.7VDC | 54.7VDC | - | - | |
|
Machine data |
Size(MM) | 400*438*88 | ||||
| Weight(KG) | 11.2 | 16.3 | 17.2 | - | - | |
| External battery UPS | ||||||
|
External battery UPS |
Battery model | Depends on the applicant | ||||
| Batteries quantity | 2/3 | 4 | 4/6 | 16-20(adjustable) | ||
| Max charging current | 1A/2A/4A/6A adjustable | |||||
| Charging voltage | 27.4VDC | 41VDC | 54.7VDC | 218.4VDC(based on 16pcs batteries) | ||
|
Machine data |
Size(MM) | 400*438*88 | ||||
| Weight(KG) | 5.6 | 8.6 | 13 | 17 | ||
| Display instructions | ||||||
| LCD |
Load size,battery capacity,mains mode,battery mode,bypass mode,fault indication | |||||
| Working environment | ||||||
| Humidity |
20-90%RH@0-40 ℃ No condensation | |||||
| Noise |
<50dBA@1M | |||||
| Control management | ||||||
| SmartRS-232/USB |
Be in favor of Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, MAC | |||||
|
Optional SNMP |
Power management supports SNMP management and network management | |||||
FAQ
What is a rack mount online UPS with lead-acid battery?
It is a rack-mountable uninterruptible power supply using true online double-conversion technology and maintenance-free lead-acid batteries, providing pure sine wave backup power for servers, network devices and data center equipment.
What models and capacities are available in the C series?
The series includes C1KR(S), C2KR(S), C3KR(S), C6KR(S) and C10KR(S), covering 1kVA, 2kVA, 3kVA, 6kVA and 10kVA.
What is the difference between standard and external-battery (S) models?
Standard models include built-in maintenance-free 12V/7Ah lead-acid batteries; external-battery (S) models connect external battery packs to extend backup runtime.
What form factor does this UPS use?
It uses a standard 19-inch 2U rack-mount design measuring 400×438×88mm, installing directly into network cabinets and server racks.
What loads can a 1-10kVA rack UPS protect?
Servers, storage, network switches, routers, industrial computers, medical and measurement equipment and other critical loads in server rooms and small data centers.
What input voltages does it support?
It supports 100-127VAC or 200-240VAC systems with a wide input range up to 110-300VAC, depending on model and load level.
Does it provide pure sine wave output with 0ms transfer?
Yes. True online double conversion delivers pure sine wave output with 0ms transfer time between mains and battery.
Can the battery runtime be extended?
Yes. External-battery (S) models support external battery packs, and the charger provides adjustable charging current up to 6A.
How is the UPS monitored and managed?
It includes an LCD display, intelligent RS-232/USB communication and optional SNMP for remote power management.
What information should I provide for a quotation?
Load list and wattage, input voltage system, required backup time, standard or external battery, quantity, destination country and certification requirements.
Get in touch with us
If you have any comments or good suggestions, please leave us a message; later our professional staff will contact you as soon as possible.