1kVA–10kVA Online UPS for Small and Medium Power Backup
1kVA-10kVA High Frequency Online UPS | True Double Conversion | PF 1.0 | 0ms Transfer | Wide Input 110-300VAC
ShanPu SP series is a single-phase high-frequency online UPS from 1kVA to 10kVA (SP1K(S)-SP10K(S), 1000W-10000W) for small server rooms, network cabinets, banking branches, clinics and light industrial loads. In its double-conversion architecture, utility AC is rectified to DC to power the inverter and charge the battery, and the inverter rebuilds regulated pure sine wave AC at power factor 1.0 with THD within 3%. On grid failure or outside the 110-300VAC / 40-70Hz window, the DC bus switches to battery with 0ms interruption. Efficiency reaches 95% in mains mode with ECO support, batteries recharge to 90% in about 6 hours, and eight socket types plus RS232/USB and optional SNMP cover global deployment.
Working Principle
Key Advantages
-
Output Power Factor 1.0 — Full KVA = Full KW: Unlike conventional UPS models with PF 0.7 or 0.8, the SP series delivers PF 1.0 output, meaning 1KVA = 1KW of usable power. A 6KVA unit provides a full 6000W to the load, maximizing actual power capacity and reducing oversizing costs.
-
True Online Double-Conversion with 0ms Transfer: Continuous AC-DC-AC conversion ensures the load is always powered by filtered, regulated inverter output — never directly connected to the raw grid. Zero transfer time during outages eliminates any risk of power disturbance to sensitive equipment.
-
Ultra-Wide Input Voltage & Frequency Range: Accepts 110–300VAC input voltage and 40–70Hz input frequency, far wider than standard UPS models. This reduces battery discharge cycles in areas with poor grid quality and ensures compatibility with generators and unstable power sources.
-
High Efficiency up to 95%: Advanced high-frequency topology achieves up to 95% conversion efficiency, minimizing energy waste and heat generation. ECO mode is available for non-critical periods, further reducing power consumption and operating costs.
-
Global Socket Options & Remote Monitoring: Eight interchangeable output socket types — Universal, UK, US, German, French, Chinese, South African and Brazilian — cover worldwide deployment requirements. Standard RS232 and optional SNMP card enable remote monitoring, automated shutdown and centralized network management.
Application Scenarios
-
Small & Medium Network Management Centers: The 1-10KVA capacity range covers small server rooms and network cabinets, delivering true online double-conversion power for switches, routers, firewalls and entry-level server clusters where clean, uninterrupted power is mandatory.
- Banking & Securities Branch Offices: Protects branch-level banking terminals, securities workstations and ATM systems. With PF 1.0 output, the full KVA rating equals usable KW power, ensuring the UPS can drive more actual load compared to traditional PF 0.7/0.8 models of the same VA rating.
- Healthcare Clinics & Medical Laboratories: Suitable for clinics, dental offices and medical laboratories powering diagnostic instruments, centrifuges and patient monitors. The ≤3% THD pure sine wave output meets medical equipment power quality requirements for stable and safe operation.
- Industrial Control & Light Manufacturing: Ideal for PLC panels, HMI terminals, small production lines and test instruments. The wide 110–300VAC input and 40–70Hz frequency tolerance handle unstable industrial grids and generator power without frequent battery switching.
-
Broadcasting, Telecom & Public Security: Supports broadcast equipment, telecom base stations, traffic signal controllers and security monitoring systems. The compact tower design with global socket options makes it suitable for international projects and multi-region deployments.
Typical Configurations
Step 1 - Size the load. Add connected wattage and choose SP1K (1000W), SP2K (2000W), SP3K (3000W), SP6K (6000W) or SP10K (10000W); PF 1.0 means KVA equals KW.
Step 2 - Choose standard or long-run. Standard models use internal 12V/7Ah batteries (2-16 pcs); (S) models accept external banks of 3-20 pcs.
Step 3 - Confirm sockets and monitoring. Select from eight socket types and plan RS232/USB or optional SNMP management.
Step 4 - Verify installation conditions. Install at 0-40°C with 20-90% RH and match charging current (1/2/4/6A).
OEM & Project Support
1–10kVA Single-Phase Online UPS for Server Rooms, Laboratory Equipment Critical Loads
ShanPu cooperates with global system integrators, EPC contractors and commercial project buyers to deliver high-capacity single-phase online double-conversion UPS solutions for medium-scale critical loads requiring extended runtime and high power quality.
Project support can include:
- 1–10kVA single-phase online UPS selection and external battery bank sizing for long backup time and future expansion
- High-reliability online double-conversion design with built-in automatic bypass and wide input voltage/frequency range
- In-depth compatibility verification with external sealed lead-acid and lithium-ion battery banks, including BMS integration and charge management
- Custom utility and battery energy-storage system matching design for continuous online operation under unstable grid conditions
- Medium-to-large batch OEM branding, private-label customization and project-specific packaging and logistics solutions
- Complete sets of IEC/CE certified technical documents, CAD drawings and on-site project consultation
- Medium-to-large volume contract terms and dedicated account support for key distribution partners
- Full-set technical guidance for extended runtime configuration, battery maintenance and standardized service schemes
Product specifications:
| Model | SP1K(S) | SP2K(S) | SP3K(S) | SP6K(S) | SP10K(S) | |
| Phase | Single-phase | |||||
| Capacity | 1KVA/1000W | 2KVA/2000W | 3KVA/3000W | 6KVA/6000W | 10KVA/10000W | |
| Input | ||||||
| Input voltage | 100/110/115/120/127VAC or 200/208/220/230/240VAC | |||||
| Voltage range | 115~300VAC | |||||
| Input frequency | 40Hz~70Hz | |||||
| Power factor | 1.0 | |||||
| Output | ||||||
| Output voltage | 100/110/115/120/127VAC or 200/208/220/230/240VCA | |||||
| AC voltage regulation | ±1% | |||||
| Frequency (synchronous range) | 47-53Hz/57-63Hz | |||||
| Frequency range (Battery Mode) | 50 Hz ± 0.25 Hz/60 Hz ± 0.3 Hz | |||||
| Current crest ratio | 3:1 | |||||
| Waveform balance |
≤3% THD Linear Load ≤6% THD Non-linear Load |
|||||
| Transfer time | 0 ms | |||||
| Output waveform | Pure Sine Wave | |||||
| Efficiencies | ||||||
| Mains mode | 93% | 93% | 95% | 93% | 94% | |
| Battery mode | 91% | 91% | 92% | 90% | 91% | |
| Battery | ||||||
| Standard UPS |
Battery model | 12V/7AH | ||||
| battery amount | 2 | 4 | 6 | 16 | 16 | |
| Charging time | 6 hours to be 90% full capacity | |||||
| Max charging current | 1A | |||||
| Charging voltage | 27.4VDC±1% | 54.7VDC±1% | 82.1VDC ± 1% | 218.4VDC ±1% | 273VDC ± 1% | |
| Machine data | Size (MM) | 280*148*220 | 395*148*220 | 425*192*320 | 500*248*616 | |
| Weight (KG) | 8.1 | 14.2 | 20.8 | 57 | 68 | |
| External battery UPS | ||||||
|
External battery UPS |
Battery model | Depends on the applicant | ||||
| Batteries quantity | 3 | 6 | 8 | 16-20 adjustable | ||
| Max charging current | 1A/2A/4A/6A adjustable | |||||
| Charging voltage | 41VDC±1% | 82.1VDC±1% | 109VDC±1% | 218.4VDC±1% | 273VDC±1% | |
|
Machine data |
Size (MM) | 280*148*220 | 460*190*330 | 425*192*320 | 500*248*460 | |
| Weight (KG) | 4.1 | 6.2 | 11 | 18 | 20 | |
| Display instructions |
||||||
| LCD |
Load size, battery capacity, mains mode, battery mode, bypass mode, fault indication | |||||
| Usage environment |
||||||
| Humidity |
20-90% RH @ 0-40 °C No condensation | |||||
| Noise |
<50dBA @ 1M | |||||
| Control management |
||||||
| SmartRS-232/USB |
Be in favor of Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, MAC | |||||
|
Optional SNMP |
Power management supports SNMP management and network management | |||||
FAQ
What is a high-frequency online UPS?
A high-frequency online UPS uses double-conversion technology with a compact high-frequency design, converting AC to DC and back to clean AC so the load always runs on regulated inverter power.
What capacity range does the SP series cover?
The SP series covers 1KVA, 2KVA, 3KVA, 6KVA and 10KVA single-phase models, rated from 1000W to 10000W with power factor 1.0.
What does power factor 1.0 mean for my load?
With PF 1.0 the KVA rating equals usable KW: a 6KVA unit delivers a full 6000W, so you avoid oversizing compared with PF 0.7 or 0.8 models.
What is the transfer time and output waveform?
The UPS provides 0ms transfer time with pure sine wave output and THD within 3% on linear loads.
What input voltage and frequency range does it accept?
It accepts 110-300VAC input voltage and 40-70Hz input frequency, which suits unstable grids and generator supply.
How efficient is the UPS?
Mains-mode efficiency reaches up to 95% depending on model, with ECO mode available for non-critical periods.
How long do the batteries take to recharge?
Standard models recharge their internal batteries to 90% in about 6 hours; long-run (S) models charge external banks with 1/2/4/6A adjustable current.
What is the difference between standard and (S) models?
Standard models include internal 12V/7Ah batteries (2-16 pcs by capacity); (S) long-run models accept external battery banks of 3-20 pcs for extended runtime.
What socket types and communication options are available?
Eight socket types are available (Universal, UK, US, German, French, Chinese, South African, Brazilian), with standard RS232/USB and an optional SNMP card.
What information should I provide for a quotation?
Please provide the required capacity, standard or long-run model, load list, backup time, voltage system, socket type, quantity and destination country.
Get in touch with us
If you have any comments or good suggestions, please leave us a message; later our professional staff will contact you as soon as possible.
© 2026 ShanPu. All Rights Reserved.